DESCRIPTION

AQUA FLASH Metal & Roof Underlayment is a durable and self adhesive membrane specifically designed to withstand the rigors of a commercial jobsite. The strong and slip resistant polyethylene surface provides a ruffed barrier to weather and moisture, UV degradation and physical damage. The proprietary asphalt adhesive layer provides exceptional thermal stability in high heat with the benefits of cold temperature application. the adhesive layer is protected with a release liner which is removed during installation.

AQUA FLASH Metal & Tile Roof Underlayment is 40 mils thick and comes in rolls 3' x 66.6' (200 square feet). AQUA FLASH Metal & Tile Roof Underlayment is cold applied and requires no heat, special adhesives or equipment.

KEY PROPERTIES

  • Superior slip resistant surface
  • Thermally stable up to 260 degrees
  • Rugged barrier against foot traffic
  • 45 day exposure time
  • Self adhesive/cold applied

USES

AQUA FLASH Metal & Tile Roof Underlayment prevents moisture entry into structures by sealing uniformly to the deck and around nail penetrations. The membrane can also be used as a temporary roof to protect the structure until the primary roofing system is installed. AQUA FLASH Metal and Tile Roof Underlayment can be exposed for a maximum of 45 days.

APPLICATION

AQUA FLASH Metal & Tile Roof Underlayment should be installed when the ambient temperature is 40 degrees F and above. All dirt, dust loose material an dother debris must be removed. AQUA FLASH Metal & Tile Roof Underlayment can be installed directly to the structural deck. Cut the membrane into manageable lengths (10' - 12'). The membrane should be aligned parallel to the roof edge and extending over the roof eave by 1/4". Fold the membrane away from the edge onto itself and remove the release liner. Place the membrane with the exposed rubberized asphalt onto the deck surface, pressing firmly into place. Overlap successive courses by 3". All end laps should overlap by 6". On all roof applications, it is necessary to nail all the overlaps of the membrane 12" on center.

DETAILS

  • All roof penetrations are to be sealed with a modified bitumen adhesive.
  • All vertical surfaces of the membrane shall turn up a minimum of 8 inches.
  • At all valleys, a continuous sheet of membrane shall be centered in the valley and overlapped by each course a minimum of 6 inches.
  • When adhering the membrane to any metal surface, an asphalt primer is required prior to application of membrane.
  • For added end lap protection, apply a coating of modified bitumen mastic underneath all overlaps.

SAFETY, HANDLING, STORAGE

AQUA FLASH Metal & Tile Roof Underlayment pallets should not be double stacked. Allow for adequate ventilation.

Consult Material Safety Data sheets for information on the safe handling, storage and personal protection, environmental and health considerations.

CODE APPROVALS AND STANDARDS

ASTM D 1970 Standard Ice Dam Underlayment

TECHNICAL DATA TABLE

PROPERTY

TEST METHOD

MINIMUM VALUE

Tensile Strength

ASTM D 412

25 lbs/in (psi)

Permeance

ASTM E 96

.01 perms (max)

Elongation (rubberized asphalt)

ASTM D 412

250%

Low Temperature Flexibility -25 F (-32 degrees C)

ASTM D 1970

no change

Adhesion to Plywood

ASTM D 903

9 lb/in (528 N/M)

www.fiberwebflashing.com | fiberweb@verizon.net | © 2010 Clark/Hammerbeam Corp.